Dual set point pressure SWICHGAGE® instruments for Lube pressure protection of variable speed engines and transmissions.

Some diesel engines, notably Detroit Diesel, Cummins and some marine transmissions, have a low oil pressure reading at idle speed relative to that at rated speed. In variable speed applications an alarm or shutdown contact set low enough to prevent nuisance alarm or shutdown at idle speed doesn't provide adequate oil pressure protection at rated speed. Murphy's "ABS" option for the pressure SWICHGAGE® features 2-set points that provide the required protection by automatically switching the contact set point according to the speed of the engine. Thus, the engine or transmission is protected from low oil pressure situations at both running speed and idle speed at a pressure setting which provides adequate lubrication.

Several devices can be used to sense engine speed and provide the switching signal for the "ABS" option. The most accurate and easily installed device is the SS100 speed switch. This speed switch can operate from either a magnetic sensor or from the AC (tachometer) terminal of the battery charging alternator. Wiring is shown below.

 

Hookup Drawing for Application Tip