EMS 227 Description
|
The EMS227 Electronic Monitoring System / Controller is
micro-processor based for monitoring and control of equipment functions. Current
applications for the EMS227 include the following:
 | Center Pivot Irrigation Control |
 | Wind Machine Auto Start |
 | Timed Irrigation Control with Automatic Cooldown and Shutdown |
Operating data is displayed on a custom icon based liquid
crystal display. Operating parameters such as oil pressure, engine temperature,
engine speed, battery voltage, fuel level, and engine running hours can be displayed.
The EMS operating parameters are configured through a simple
three-button interface. Access to the system memory is controlled by an entry code. You
can change such parameters as shutdown set-points, operating delays, and throttle
parameters.
Standard Program Features
An on-board hourmeter keeps a log of equipment running hours.
Ramp Oil pressure monitoring protects equipment at both high rated speed and low idle
speed. Programs may also include some of these features:
 | Basic start / stop |
 | Engine warm-up / cooldown |
 | Delay on start / stop |
 | Automatic throttling |
 | Prelube / glowplug functions. |
To see a list of standard programs available for this platform,
click here.
|
EMS 227 Specifications
| Input Voltage |
10 to 28 VDC |
| Operating Temperature |
-4 to 149 °F (-20 to 65 °C) |
| Storage Temperature |
-4 to 149 °F (-20 to 65 °C) |
| Display |
Custom direct driven icon based liquid
crystal. |
| Digital Inputs |
8 optically isolated inputs (positive voltage
or ground) |
| Analog Inputs |
5 inputs - accepts a variety of resistive
sending units, 4-20 ma or 0-5 VDC sources. |
| Frequency Input |
1 optically isolated input for speed
reference. 3 VAC RMS required below 100 Hz and 2 VAC RMS required above 100Hz.
Frequency Range is 30 to 10,000 Hz. |
| Transistor Outputs |
4 rated at 200 mA sinking. |
| Relay Outputs |
4 SPST B+ rated 3A @ 30 VDC N.O. |
|