EnerGenius® NRG Benefits
For the first time, your battery charger can warn you
before battery system problems threaten your mission-critical
application.
The new BatterySENS fault warning system, teamed with extreme charging
accuracy, helps prevent the No. 1 problem with generator sets: failure
to start. EnerGenius NRG is even smart enough to detect installation
errors, adjust in the field to different inputs, and prevent “fried”
electronics.
|
EnerGenius NRG Battery Charger Features 
| Designed from the ground up for mission-critical
reliability |
| •
Precise charging and temperature compensation assure the correct battery
charge under all conditions. |
| •
The industry-first BatterySENS feature warns of high resistance battery
or connections, so service can be dispatched before engine start is
needed. |
| |
| EnerGenius NRG puts you in control. At any
time, select from or change: |
•
Input: 120, 208 or 240 volts
•
Output: 12 or 24 volts nominal (optional)
• Battery type from six
standard settings
• Enabled or disabled automatic
fast charging
• Enabled or disabled automatic
temperature compensation, or installation of optional remote temperature
sensor. |
| |
|
| Intelligent features prevent installation
errors |
•
EnerGenius won’t start if the battery is connected backwards,
disconnected or the wrong voltage
• Each fault activates SENS’s
unique “Battery Fault” alarm. |
| |
|
| Replace nearly any existing
charger without planning ahead |
| •
EnerGenius NRG is adaptable in the field to different inputs, as well as
to battery voltage and type. |
| |
| Intelligent features prevent system damage |
•
Industry-first, load-dump protection clamps high-voltage
transients.
•
Class-leading surge suppression provides the best lightning
protection available. |
| |
|
Easy field battery upgrades
• In seconds select the new
correct battery voltage from six standard settings. |
| |
|
| Engineered for top quality and reliability |
•
Highest possible ISO 9000 quality design and construction
•
Finest industrial-grade components available
• Long, comprehensive warranty
• UL, C-UL listed, CE marked
(50 Hz units) |

EnerGenius Battery Charger Features, Benefits and Specifications
|
| Feature:
Configurable to nearly any site |
Benefit
• Easiest
field adjustments for any battery; can replace nearly any
charger |
| Specifications |
|
•
|
120/208-240 volt AC input
selector switch |
|
|
•
|
12/24 volt output field
programmable (optional) |
|
•
|
6 discrete battery voltage programs |
|
•
|
Lead-acid 12 or 24-volt |
|
|
- Low or high S.G. flooded |
|
|
- Low or high SG VRLA |
|
•
|
Nickel cadmium |
|
|
- 12-volt: 9 or 10 cells |
|
|
- 24-volt: 18, 19 or 20 cells |
|
•
|
Enable or disable automatic fast
charge |
|
•
|
Enable or disable
temperature compensation |
|
•
|
Optional remote temperature sensor |
|
•
|
Dead battery charge
feature
|
| |
|
|
| Feature:
Highest accuracy charging |
|
Benefit
•Best battery performance and
longest battery life ensure engine start
|
| Specifications |
|
•
|
10 or 20 amp output |
Standard 4-Rate Charging
|
|
•
|
Highest accuracy (+0.5%) line and
load regulation |
|
•
|
4-rate fast charge program |
|
|
- Constant current charge |
|
|
- High-rate taper charge |
|
|
- Finishing charge |
|
|
- Maintaining charge |
|
•
|
Temperature compensation
(enable or disable in field) |
|
•
|
Optional remote temperature sensor
|
| |
Standard Temperature Compensation
|
|

|
| Feature:
Comprehensive display and alarm system |
Benefits
•Gives the most complete system
status and diagnostics available
•Optional alarm system “C” exceeds NFPA 110 requirements |
| Specifications |
 |
|
•
|
Digital meter accurate to +2%
voltage and +5% amperes |
|
•
|
Battery fault alarm indicates any of
the following |
|
|
-Battery disconnected |
|
|
-Battery polarity reversed |
|
|
-Mismatched charger/battery voltage |
| |
-Open charger to battery connection |
|
|
-Open battery cell or excessive
internal resistance |
|
|
|
| Feature:
Industry-first battery fault warning |
|
Benefit
•Helps diagnose battery problems before engine start is needed |
| Specifications |
| • |
Charger issues a battery fault alarm
if the battery: |
| |
- Becomes disconnected, fails open
circuit, or if internal resistance becomes high
|
|

|
| Feature:
Ruggedized to the toughest specifications |
Benefit
•Reliable charger stays accurate
despite severe real-world conditions to ensure dependable engine
starting |
| Specifications |
|
•
|
Electronic current limit prevents
overloads |
| • |
BatterySENS protects against reverse
or wrong battery voltage |
| • |
Operating temperature: -40C to +60C.
Meets full specification from -20C to +45C. |
| • |
Thermal protection against excessive temperature |
|
| • |
Humidity 5% to 95%, non-condensing |
|
| • |
Conformally coated printed circuit card |
|
| • |
Vibration resistance to UL 991, Class B
(10A units only) |
|
| • |
Lightning transient immunity to ANSI/IEEE C62.41
Cat. B |
|

| Feature:
Safety and EMC compliance |
Benefit
•Meets
USA, Canada and European Union standards. Approved
for use with UL 2200 gensets. |
| Specifications |
| • |
C-UL listed to UL 1236 and 1012 |
 |
| • |
UL listed in category BBHH for “Emergency Power
Systems” (optional) |
| • |
Complies with CSA 22.2 no. 107.2-M89 |
| • |
Meets FCC Part 15, Class B |
|
| • |
CE marked (50 Hz units) to EN 60335 |
 |
| • |
Input and output fuses |
| • |
Complies with NFPA 110 (requires optional alarms
“C”) |
|

|
| Feature
State-of-the-art mechanical design |
|
Benefit
•Anodized
aluminum housing offers long-lived, cool operation |
| Specifications |
|
•Natural convection cooling |
|
•Corrosion-resistant housing with conduit knockouts |
|
•Terminal blocks for permanent installation |
| |
|
| |
|
| |
|
| Housing Dimensions |


EnerGenius Ordering/Model Information
10-Amp Chargers

20-Amp Chargers


|
Download Catalog Sheet |